欧美日韩福利视频亚洲福利_国產免費AV黄色一级片_性感少妇A V无码_午夜人妻影院5566中文字幕_欧美综合网五月天_欧美特级特黄a大片免费_国产又色又爽又黄的视频网站_亚洲激情一二三四入口少妇_色爽爽网站免费看_亚洲精品综合第二区

聯(lián)系我們

 

聯(lián)系我們

浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司
電話:0632-5667636
傳真:0632-5667636
手機(jī):15562228838,13963221227

地址:山東滕州市平行路(商務(wù)部和技術(shù)部)
郵箱:wangxiaoying9@126.com
QQ:1404939462
聯(lián)系人:王經(jīng)理
網(wǎng)址:lirwjob.com.cn

毛細(xì)管色譜柱氣相色譜法測定工作場所空氣中三乙胺
  • 毛細(xì)管色譜柱氣相色譜法測定工作場所空氣中三乙胺

  • 發(fā)布時間:2025-7-7 10:25:19
  • 產(chǎn)品簡介:
    名稱:毛細(xì)管柱
    規(guī)格:30m*0.53mm*3um
咨詢熱線:0632-5667636

浩瀚色譜建立優(yōu)化使用毛細(xì)管色譜柱溶劑解析氣相色譜法測定工作場所空氣中三乙胺的方法研究。方法采用堿性硅膠管采集工作場所中的三乙胺,加入硫酸與氫氧化鈉解析,使用HH-1色譜柱分離,FID測定。結(jié)果該方法三乙胺檢出限為0.5μg/ml,線性范圍為0.5~1 340.0μg/ml,最低檢出濃度為0.13 mg/m3(以采集7.5 L空氣樣品計);相對標(biāo)準(zhǔn)偏差為0.63%~3.31%,解析效率為99.5%~100.6%,加標(biāo)回收率為98.2%~101.8%,樣品在室溫下至少可保存7 d。結(jié)論該方法適用于工作場所空氣中三乙胺的測定。

?

本標(biāo)準(zhǔn)規(guī)定了測定固定污染源廢氣中三乙胺的氣相色譜方法。
本標(biāo)準(zhǔn)適用于固定污染源有組織排放和無組織排放的三乙胺濃度的測定。
在有組織排放和無組織排放監(jiān)測中,采樣體積為10 L時(標(biāo)準(zhǔn)狀態(tài)),方法檢出限為0.15mg/m3,采樣體積為30 L時(標(biāo)準(zhǔn)狀態(tài)),方法檢出限為0.05 mg/m3。

名稱:毛細(xì)管柱
規(guī)格:30m*0.53mm*3um
型號:HH-1
應(yīng)用:固定污染源廢氣中三乙胺的氣相色譜方法

?

5A分子篩填充柱

?

Hao Han Chromatography established and optimized a method for the determination of triethylamine in workplace air using capillary chromatography column solvent resolution gas chromatography. The method uses an alkaline silica gel tube to collect triethylamine in the workplace, adds sulfuric acid and sodium hydroxide for resolution, uses HH-1 chromatography column for separation, and uses FID for determination. Results The detection limit of triethylamine in this method is 0.5 μg/ml, the linear range is 0.5~1 340.0 μg/ml, the lowest detection concentration is 0.13 mg/m3 (based on collecting 7.5 L of air samples); the relative standard deviation is 0.63%~3.31%, the resolution efficiency is 99.5%~100.6%, the spiked recovery is 98.2%~101.8%, and the sample can be stored at room temperature for at least 7 days. Conclusion This method is suitable for the determination of triethylamine in workplace air.

This standard specifies the gas chromatography method for determining triethylamine in exhaust gas from stationary pollution sources.

This standard is applicable to the determination of triethylamine concentration in the organized and unorganized emissions of fixed pollution sources.

In the monitoring of organized and unorganized emissions, the detection limit of the method is 0.15 mg/m3 when the sampling volume is 10 L (standard state), and the detection limit of the method is 0.05 mg/m3 when the sampling volume is 30 L (standard state).

Name: Capillary column

Specification: 30m*0.53mm*3um

Model: HH-1

Application: Gas Chromatographic Method for Determination of Triethylamine in Waste Gas from Stationary Sources

聯(lián)系人
手機(jī)號碼
電子郵件
驗證碼
看不清楚?點擊換張圖片
我要評論:

(內(nèi)容最多500個漢字,1000個字符)

驗 證 碼 :
提交信息
網(wǎng)站ICP備案號:魯ICP備18012860號

魯公網(wǎng)安備: 37048102006522號

浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司
地址:山東滕州市平行路(商務(wù)部和技術(shù)部)
電話:0632-5667636   傳真:0632-5667636
手機(jī):15562228838,13963221227  郵箱:wangxiaoying9@126.com

 

技術(shù)支持:牽牛建站 | 中科商務(wù)網(wǎng)  | 網(wǎng)站管理